California ISO
Public & Media Operations Center
Operations Center

Direct Telemetry (RIG/DPG)

Back to Previous Page
 Download Adobe Reader
Formerly Generator Communications Project (GCP) and Participating Loads Project (PLP).
Technical requirements and standards for use by Generating Units and Load Participants to establish and maintain a Data Processing Gateway (DPG) between plant facilities and the ISO Energy Management System (EMS). These specifications serve as the primary means for secure telemetry between a Generator or Load Participant and the EMS for the purpose of generation control and monitoring, and as a prerequisite for participation in the ISO markets.

What is GCP Phase I?
pdf 12K | Abstract | 02/15/2001 18:32

AGC Participant Requirements
ISO Generation Monitoring and Control Requirements - AGC/Regulation Units
pdf 377K | Abstract | 02/26/2007 15:35
RIG Technical Specification
pdf 335K | Abstract | 02/26/2007 15:58
Validated RIGs
pdf 11K | Abstract | 02/26/2007 16:00
RIG Third Party Engineering Firms
pdf 72K | Abstract | 03/14/2008 16:10
RIG Engineering Contacts
pdf 60K | Abstract | 10/30/2007 07:52
RIG Engineering and Deployment Guide
pdf 207K | Abstract | 10/30/2007 11:28
RIG Acceptance Test (RAT) Procedures
pdf 167K | Abstract | 02/26/2007 15:55

Non-AGC Requirements
ISO Monitoring and Communication Requirements - Non-AGC Units Providing Ancillary Services
pdf 405K | Abstract | 02/26/2007 15:40
DPG Technical Specification
pdf 359K | Abstract | 02/26/2007 15:20
Validated DPGs
pdf 11K | Abstract | 02/26/2007 16:01
DPG Third Party Engineering Firms
pdf 72K | Abstract | 03/14/2008 16:12
RIG Engineering Contacts
pdf 60K | Abstract | 10/30/2007 07:52
DPG Engineering and Deployment Guide
pdf 193K | Abstract | 02/26/2007 14:54
DPG Generation Acceptance Test Procedures
pdf 178K | Abstract | 02/26/2007 15:17

Energy Only and Supplemental Energy Requirements
ISO Monitoring and Communications Requirements - Generating Units Providing Only Energy and Supplemental Energy
pdf 409K | Abstract | 02/26/2007 15:26
ISO Monitoring and Communications Requirements - Qualifying Facilities (QF) Providing Only Energy and Supplemental Energy
pdf 375K | Abstract | 02/26/2007 15:47
DPG Technical Specification
pdf 359K | Abstract | 02/26/2007 15:20
Validated DPGs
pdf 11K | Abstract | 02/26/2007 16:01
DPG Third Party Engineering Firms
pdf 72K | Abstract | 03/14/2008 16:12
RIG Engineering Contacts
pdf 60K | Abstract | 10/30/2007 07:52
DPG Engineering and Deployment Guide
pdf 193K | Abstract | 02/26/2007 14:54
DPG Generation Acceptance Test Procedures
pdf 178K | Abstract | 02/26/2007 15:17

Participating Load Requirements
ISO Monitoring and Communication Requirements - Non-AGC Units Providing Ancillary Services
pdf 405K | Abstract | 02/26/2007 15:40
Participating Load Technical Standard
pdf 315K | Abstract | 02/26/2007 15:43
DPG Technical Specification
pdf 359K | Abstract | 02/26/2007 15:20
Validated DPGs
pdf 11K | Abstract | 02/26/2007 16:01
DPG Third Party Engineering Firms
pdf 72K | Abstract | 03/14/2008 16:12
RIG Engineering Contacts
pdf 60K | Abstract | 10/30/2007 07:52
DPG Engineering and Deployment Guide
pdf 193K | Abstract | 02/26/2007 14:54
Participating Load Acceptance Test
pdf 134K | Abstract | 02/14/2001 09:59

Security Requirements
Certification Practice Statement for Generator Communications Project Certification Authority
pdf 177K | Abstract | 07/11/2006 08:41

© 2005 -  California ISO
All Rights Reserved